Follow us :

IN-RC3 5t10t20t30t Canister Column Compression Load Cell for truck scale

IN-RC3 5t10t20t30t Canister Column Compression Load Cell for truck scale
FOB Price

US $200.001 - 10 piece

US $150.0011 - 100 piece

US $100.00101 - 500 piece

group name
canister and compression load cell
Min Order
1 piece
brand name
Inntronic
model
IN-RC3
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, FCA, CPT, DDU, Express Delivery
Acceptable payment methods
T/T, L/C, PayPal, Westem Union
update time
Thu, 21 Feb 2019 13:53:58 GMT

Paramtents

  • Pattern Column Cylinder Type

  • Transform Type Resistance Strain

  • Out-Wire 4-Wire

  • Output Signal Type Analog Type

  • Material Stainless Steel/Alloy Steel

  • Capacity 5T, 10T, 20T, 30T

  • IP Rating IP68

  • Application Truck Scale

  • Accuracy OIML C2 C3

  • Creep(dcr) over 30 min. ± 0.030 ± 0.0167 %ofCn

Packging & Delivery

  • 32cm x 26cm x 27cm
  • Min Order1 piece

Briefing

load cell factory in China, canister compression load cell,Analog Load Cell,Stainless Steel/Alloy Steel

Detailed

IN-RC3 Canister Column Compression Load Cell 

              

Item

Unit

Parameter

Accuracy class to OIML R60

 

C2

C3

Rated capacity (Emax)

 

51020 30

Minimum LC verification interval (Vmin)

%ofEmax

0.0200

0.0100

Sensitivity (Cn) I Zero balance

mV/V

2.0±0.002 I 0± 0.02

Temperature effect on zero balance (TKo)

% ofCn/10K

± 0.02

± 0.0170

Temperature effect on sensitivity (TKc)

 

% ofCn/10K

± 0.02

± 0.0170

Hysteresis error (dhy)

%ofCn

± 0.0270

± 0.0180

Non-linearity(dlin)  

%ofCn

± 0.0250

± 0.0167

Creep(dcr) over 30 min.

%ofCn

± 0.030

± 0.0167

 

Input  (RLC) &Output resistance (Ro)

 

 Ώ

IN-RC3:400±10&352±3

IN-RC3Y:700 ±20 &706±7

Nominal range of excitation voltage (Bu)

V

5---15

Insulation resistance (Ris) at 50Vdc

MQ

5000

Service temperature  range   (Btu)

-30...+70

Safe load limit (EL) & Breaking 10ad(Ed)

%ofEmax

150 &250

Protection class according to EN 60 529  (IEC 529)

 

IP68

Material :Measuring element+housing

 

Stainless or alloy steel +Stainless steel

 

Maximum capacity(Emax)

 

5t

10t

20t

30t

Min. scale verification (emin) according to EN45501 [...#=max.Number of load cells]

 

kg

 

2

[4#]

 

5

[6#]

 

5

[6#]

 

10

[10#]

Deflection at  Emax (snom) approx

mm

0.55

0.55

0.65

0.75

Weight(G) approx

kg

1.8

1.9

2.1

2.3

Cable : DiameterØ 6mm Length

m

8

10

12

15