Digital load cell system is a new type of electronic weighing technology developed on the basis of traditional resistance strain sensor combined with modern microelectronics technology and microcomputer technology integration. It is composed of analog sensors (resistance strain type) and digital conversion module two parts. Digital modules aremade from highly integrated electronic circuits fabric...
timeMon, 12 Feb 2018 22:06:35 GMT
Ourcompany, INNOVATION GROUP LIMITED, is a professional manufacturer of all kindsof professional in the automation fieldfor many years, with strength of customized items, and providing the systemsolutions, with good quality and pretty competitive price.
timeFri, 08 Dec 2017 23:24:17 GMT
Our main products are Including Kinds ofload cell (load pin, column canister load cell, mini load cell, force sensor, Stype load cell, shear beam load cell, tension and compression load cell,and kinds of special designed load cell.), bench scale (high precision bench scalelike 150kg/1g, 100kg/1g,etc.), floor scale(high precision floor scale, complywith OIML C3,C5,C6.), truck scale (normal truck sc...
timeWed, 29 Nov 2017 23:19:13 GMT
Ourproducts are applying in the fields like food & beverage plant, water andwaste water treatment, oil & gas, electric power, scientific research,ocean, boiler, coal mine, forklift weighing system, HVAC systems, aircondition, fuel pressure measurement and other process control industries.
timeSat, 25 Nov 2017 22:04:09 GMT
Wehave a complete quality control system, all of our products are fully checkedby IQC, OQC departments before ship to our clients.
timeFri, 24 Nov 2017 20:33:18 GMT
No MOQ limits, so 1 piece for test purposeat first is acceptable.
timeThu, 23 Nov 2017 22:09:12 GMT
A combination weigher comprises a collecting conveyor which conveysobjects and discharges the objects; a plurality of weighing conveyorsconfigured to convey the objects fed thereto and discharge the objects, to feedthe objects to the collecting conveyor apparatus; a plurality of weight sensorsfor measuring weights of the objects held on the weighing conveyors; and acontrol section. It's suitable t...
timeWed, 22 Nov 2017 22:18:24 GMT
Elevator Weight limiter should work together with elevator load cells. Can administrate the actual weight of the elevator, when the weight is over, it will alarm and cut down the power, to keep the stable operation of the elevator. This weighing limiter can be used with elevator load cell, lifting load cell, crane load cell, engineering vehicle load cell,and Industria...
timeSat, 21 Oct 2017 20:30:30 GMT
The output of the load cell at no load, normally quoted as a percentage of full load. Also know as zero offset.for example,if your load cell is 3kg, conect the power to the load cell, us mv indicator to test the output of the current load cell (without any load on the load cell) , then the test result is the zero
timeThu, 10 Aug 2017 21:18:37 GMT
Normally quoted as either a percentage of full scale output or a percentage of the applied load. The accuracy figure is the combined error caused by non linearity, repeatability and hysteresis error values in the load cell.
timeThu, 10 Aug 2017 21:17:26 GMT
When a load cell is taken from zero to full load and back to zero the mV output for a given load value will be slightly different when the load is rising to when the load is falling. The maximum difference is used to calculate the hysteresis. Normally quoted as a percentage of full load.
timeThu, 10 Aug 2017 21:15:42 GMT
Temperature effect on span of load cell usually quoted as a percentage of full scale this is the change in output at full load due to temperature changes. e.g. 0.01%/10°C means a change of up to 0.01% of full load output per temperature change of 10 degrees C. This function is very important for the load cell application in different temperature. without temperature compensation, the accuracy will...
timeSat, 05 Aug 2017 13:19:02 GMT
A measure of the ability of the load cell to repeatedly give the same output for the same load under the same conditions. The error is normally quoted as a percentage of full load.This specification is very important to a weighing scale. If every weighing, the reading is too much different, it means that the weighing scale or electronic balance, or load cell is bad quality.
timeSat, 05 Aug 2017 12:49:36 GMT
The creep of a load cell means: when load cell is in stable environment( for example, temperature, humidity) and other changeable aspects keep no change (for example: estable force system, load andother aspects),when load cell is loaded quickly a nominal load and unload thenominal load, within a certain time, the output of load cell changes with time.the normal creep have two types: positive creep...
timeSat, 05 Aug 2017 11:57:43 GMT
The material is fed into the weighing hopper by the feed equipment(such as vibrating screen, belt conveyor, etc.) in batches according to the set value. The weighing hopper is supported by three load cells(IN-BBS、IN-WB、IN-WBL33Share Beam Load Cell) located on the support frame. When the material is fed into the hopper, the weight valueis passed to the China innovation load cell, with stable creep,...
timeSat, 05 Aug 2017 11:54:25 GMT
网络文化经营许可证:浙网文[2013]0268-027号|增值电信业务经营许可证:浙B2-20080224-1 2007-2024 Tradevv.com. All rights reserved.